14. TROUBLESHOOTING

NOTE: All PM15E positioners are serialized and date coded. Please
note date, and provide the serial number when contacting the factory
for troubleshooting or service.

Signal change results in actuator running to end positions:

_____

Check coupling between positioner and actuator.

_____

Check cam position and locking screw.

_____

Check input signal.

Signal change has no effect on the actuator position:

_____

Check indicator and screw.

_____

Check air supply to positioner and tubing to the actuator.

_____

Check input signal to positioner.

_____

Check diaphragm for damage or leakage.

_____

Check pilot valve function.

_____

Check cam for correct setting.

_____

Check I/P output.

Inaccurate positioning:

_____

Dirty or worn pilot valve.

_____

Defective or leaking diaphragm.

_____

Input signal fluctuates.

_____

Incorrect sizing of actuator.

_____

Valve/actuator “stiction”.

_____

High valve/actuator breakaway torque.

_____

Loose cam.

15. TECHNICAL DATA

Input Signal

4-20 mA

Linearity

< 0.75%*

Hysteresis

< 1%*

Repeatability

< 0.5%*

80% Load (Supply Pressure 87 psi)

1,000 (kPa/kPa) (psi/psi)

50% Load (Supply Pressure 87 psi)

1,250 (kPa/kPa) (psi/psi)

Air Consumption at Supply Pressure

± 20%

0.2 MPa/29 psi

6.1 nl/min 0.22 SCFM

0.4 MPa/58 psi

13.6 nl/min 0.48 SCFM

0.6 MPa/87 psi

22 nl/min 0.78 SCFM

0.8 MPa/116 psi

30.5 nl/min 1.08 SCFM

1 MPa/145 psi

39 nl/min 1.38 SCFM

Air Delivery at Supply Pressure

± 20%

0.2 MPa/29 psi

200 nl/min 6.9 SCFM

0.4 MPa/58 psi

370 nl/min 12.8 SCFM

0.6 MPa/87 psi

540 nl/min 18.8 SCFM

0.8 MPa/116 psi

710 nl/min 24.7 SCFM

1 MPa/145 psi

880 nl/min 30.6 SCFM

Supply Pressure

0.15-0.9 MPa/21.8-125 psi

Temperature Range

-20°C to +85°C
(-4°F to 185°F)

Connector Threads

1

/

4

" NPT

Gauge Threads

1

/

8

" NPT

Weight Std.

1.5 kg/3.4 lbs.

Weight with Gauges

1.8 kg/3.9 lbs.

Ingress Protection

IP 66/NEMA Type 4

*Percent of full scale.

Flow Control Division

Worcester Controls

10

Model PM15E Electro-Pneumatic Valve Positioner

WCAIM2017