Automax Logix 3200IQ Digital Positioner

Installation, Operation and Maintenance Instructions

Maintenance and Repair

Driver Module Assembly

The driver module assembly moves the spool valve by
means of a differential pressure across its diaphragm. Air
is routed to the driver module from the regulator through
a flexible hose. A barbed fitting connects the flexible hose
to the driver module assembly. Wires from the driver
module assembly connect the hall effect sensor and the
piezo valve modulator to the main PCB assembly.

Driver Module Assembly Replacement

To replace the driver module assembly, refer to Figures
14-18 and 28 and proceed as outlined below. The
following tools are required:

• Flat plate or bar about 1⁄ 8" thick

• Phillips screwdriver

• 1/4" nutdriver

WARNING: Observe precautions for handling
electrostatically sensitive devices.

Figure 14: Driver Module Assembly

1. Make sure the valve is bypassed or in a safe condition.
2. Disconnect the power and air supply to the unit.
3. Remove the driver module cover (Figure 17), using a

flat bar or plate in the slot to turn the cover.

4. Remove the spool valve cover by removing the screw

and sliding the cover assembly backwards until the tab
is clear of the slot (Figure 15). The sheet metal cap,
hydrophobic filter and O-ring should be removed with
the spool valve cover. It is not necessary to take these
parts out of the spool valve cover.

Figure 15: Spool Valve Cover Assembly

Figure 16: Spool and Block

5. Being careful not to lose the nylon washer, remove the

Phillips-head screw that attaches the driver module to
the main housing (Figure 16).

WARNING: Spool (extending from the driver module
assembly) is easily damaged. Use extreme caution
when handling spool and spool valve block. Do not
handle the spool by the machined portions of spool.
The tolerances between the block and spool are
extremely tight. Contamination in the block or on the
spool may cause the spool to hang.

6. Remove the spool valve block by removing the two

Phillips-head screws and carefully sliding the block off
the spool (Figure 16).

7. Carefully remove the spool by sliding the end of the

spool out of the connection clip. Excessive force may
bend spool.

8. Remove the main cover.
9. Remove the plastic board cover by removing the three

retaining screws (see Figure 17).

Pressure Sensor Board

Hall Sensor
Connection

Pressure
Modulator
Connection

O-ring

Driver Module
Assembly

Analog
Output

Board

Connection

Analog
Output Board

Install Barbed Fitting after
Driver Module is in housing

Hall Sensor Connector

Pressure Modulator Connector

Position wires
to the rear
of Modulator

Regulator

Pressure Sensor
Board Connection

User Interface
Board Connection

Stem Position
Sensor
Connection

Main PCB
Retaining
Screw

Screw

Spool Valve Cover

Spool Valve
Screw

Nylon
Gasket

Driver to
Housing Screw

Spool

Spool
Valve
Block

Housing

Advertising