Fronius IG 300 User Manual

Page 44

Advertising
background image

36

2.

Fan controller ready for operation

-

Press „Enter“ key (D)

3.

Start fan controller test

-

Press „Enter“ key (D)

4a. The fan controller is tested.
-

This involves the roof fans running for
approx. 20 seconds.

4b. If a fault is detected on the fan cont-

roller or one or more roof fans:

-

„Safety / Stop“ is displayed instead of
„Test / Run“

-

A defect on a fan means that the fan
controller cannot be tested until later

-

The number „1-15“ indicates which
roof fans are defective or have no
power supply

(C)

(C)

(D)

(C)

(D)

(D)

(B)

1.

„State Fan“ ... Queries status for the
fan controller

-

Initiating „State Fan“ setting: Press
„Enter“ key (D)

(B)

(A)

(C)

(D)

=

~

0

No fan defective / lacking power supply

1

BR

2

BL

3

BR and BL

4

FR

5

FR and BR

6

FR and BL

7

FR, BL and BR

8

FL

9

FL, BR

10

FL, BL

11

FL, BL and BR

12

FL, FR

13

FL, FR and BR

14

FL, FR and BL

15

All roof fans defective / lacking power supply

FL

FR

BL

BR

Fig. 4 - Code for roof fan

Advertising