2.0 Installation and Operation Overview

RN-8200 Reference Manual

Page 2-5

2.2.2 RS-232 Remote Host Port Cabling (DB9

The RN-8200 Rack Unit has a standard RS-232
(DB9F) communication port that connects the host PC
to the RN-8200 Rack Unit allowing the CU software
control and configuration.

Cable Type (supplied): Straight through DB-9 Male
(To mate with Female on RN-8200 Base) to DB-9
Male (to mate with DB-9 Male on typical PC COMM
port).

Recommended Maximum Length: 50 ft

7

5

8

3

2

RX

TX

RTS

GND

CTS

DB9M

(DTE)

7

5

8

3

2

DB9F

CABLE

GND

RX

TX

PC

(typical)

DB9M

RTS

CTS

7

5

8

3

2

7

5

8

3

2

Optional Flow Control Connections

If the device requires DSR, CD, or DTR,

implement loop -back handshake at the

device end of the cable as shown .

RN Remote

RS-232

Host Port

4

2

6

DTR

CD

DSR

4

2

6

2.2.3 RS-232 Control Port Cabling (3 wire interface)

5

3

2

RX

TX

GND

DB9M

(DTE)

5

3

2

G

Rx

Tx

DB9F

CABLE

GND

RX

TX

PC or

A/V

DEVICE

ControlMate

Port

1, 2, 3, or 4

Serial Control Port for Control of DTE Devices

5

3

2

TX

RX

GND

DB9F

(DCE)

5

3

2

G

Tx

Rx

DB9M

CABLE

GND

TX

RX

A/V

DEVICE

ControlMate

Port

1, 2, 3, or 4

Serial Control Port for Control of DCE Devices

7

8

RTS

CTS

7

8

4

2

6

DTR

CD

DSR

4

2

6

Optional Flow Control Connections

If the device requires

handshake, implement

loop-back handshake at

the device end of the

cable as shown.

Advertising