OPERATION

28-

DIXON

WARNING!
Lead-acid batteries generate

explosive gases. Keep sparks,

flame and smoking materials

away from batteries. Always

wear eye protection when around

batteries.

Weak Battery

If your battery is too weak to start the engine, it should

be recharged. (See “Battery” in the Maintenance

Section.)

If “jumper cables” are used for emergency starting,

follow this procedure:
Jumper Cables

Connect each end of the RED cable to the

1.

POSITIVE (+) terminal on each battery, taking

care not to short against chassis.
Connect one end of the BLACK cable to the

2.

NEGATIVE (-) terminal of the fully charged

battery.
Connect the other end of the BLACK cable to

3.

a good CHASSIS GROUND on the mower with

the discharged battery, away from the fuel tank

and battery.

To remove cables, reverse order

Remove BLACK cable first from chassis and

1.

then from the fully charged battery.
Remove RED cable last from both batteries.

2.

IMPORTANT INFORMATION
Your mower is equipped with a 12-volt

negative grounded system. The other vehicle

must also be a 12-volt negative grounded

system. Do not use your mower to start other

vehicles.

8011-642

Jumper cable connection