Ethernet

The Ethernet connector, plug J1, is located on the termination PCBA, and is reserved for future
implementation.

Power

The terminal block TB6, labeled CLASS

2

12

–24

VDC

is located on the termination PCBA. It provides

power connection for the AMI.

Table 6. Power Assignment

Metalwork
Label

Internal Terminal
Pin-Out


Function or ACT Description

+

TB6-1

Positive terminal of external power supply
(Black wire with white stripe from power supply)

TB6-2

Negative terminal of external power supply
(Solid black wire from power supply)

GND TB6-3

Frame

ground

Optional PBX Connection

The PBX connector is located on the optional telephone interface PCBA, and provides connection to a
standard PBX analog station port. It may be used as a plug-in connection or with the terminal screws
designated for tip (green) and ring (red).

Page/Party

®

The connector P1 is located on the Page/Party

®

Interface PCBA and provides connection to a Page/Party

®

system.

Table 7. Page/Party

®

Assignment

Metalwork
Label

Internal Terminal
Pin-Out


Function or ACT Description

Party L1

P1-1

The 33-ohm line interface to GAI-Tronics party line.
Internal 33-ohm termination.

Party L2

P1-2

Page L1

P1-3

The 33-ohm line interface to GAI-Tronics page line.
External 33-ohm termination required.

Page L2

P1-4

N

OTE

: Pin 1 on this connector is on the right side.