Installation manual masterline extreme hybrid – HUBER+SUHNER MASTERLINE Extreme Hybrid User Manual
Page 6
HUBER+SUHNER disclaims any liability resulting from incorrect installation and use, including any damages resulting from the use of
tools and accessories other than the ones recommended herein. Any installation performed by unqualified personnel voids the product
warranty provided by HUBER+SUHNER. All due care and attention must be exercised when performing the installation of these pro-
ducts. For advice concerning the general handling of these products please contact HUBER+SUHNER.
2.
5
Step 10
Unwrap copper tape from cable using gloves due to
potential sharp edges up to the "strip-back point".
Step 11
Make sure not to leave any sharp edges where the
copper foil goes under the jacket: carefully remove
excess foil with pin-nosed pliers and then cover it with
tape.
Step 12
Carefully unwind the fibre optic cable element from
the DC tails and from a loop to separate it.
Step 13
During this process (at any stage) ensure the fibre optics are
not kinked where they exit the cable butt.
Use tape to protect the FO cable against overbending.
Step 14
Once fiber optic cable is separated from DC wires,
attach it temporarily to base station to keep it secure
and clean.
Step 15
Tighten cable gland to secure cable and ensure IP
protection.
INSTALLATION MANUAL
MASTERLINE Extreme Hybrid