Insinger Commander 18-6 User Manual

Page 18

Advertising
background image

DoorTypeTM2013

www.insingermachine.com 800-344-4802

16

CLEANING PROCEDURES (continued)

5. Clean suction strainers of build-up.

PRESSURE ADJUSTMENT
Pressure in the final rinse must be maintained at 20

± 2 psi. Adjustment of the pressure is made with the

adjusting screw on the pressure reducing valve.

NOTE:

Improper cleaning of the suction strainers

will cause the pumps to cavitate. This will

cause poor washing results.

6. Clean the tank level float with a plastic abrasive pad (do

not use steel wool).

CAUTION:

Level floats must be cleaned daily.

Build-up of grease and dirt will cause faulty operation

of the tank fill heating system.

NOTE:

Upper and lower wash & rinse pipes are

not the same.

7. Final rinse nozzles should be cleaned of matter clogging

the jet spray.

8. The doors should be left open to allow drying of interior

surfaces.

If there are flow or pressure problems with the pressure

reducing valve, CAREFULLY remove the strainer

assembly and clean the strainer screen. Be careful

not to damage the Hex nut o-ring

NOTE:

The pressure reducing valve is supplied

only on units equipped with optional booster

PART 3 OPERATION & CLEANING INSTRUCTIONS

®