Chemicals
Upon the completed installation of the dishwasher,
contact a local detergent/chemical supplier for the
correct chemicals for your soil load and geographi-
cal area.

Electrical connection points for the detergent
dispenser and rinse injector are located inside the
control panel. Refer to the wiring diagram for this
machine for the proper connection points.

Dispensers may be connected on either the primary
voltage side of the machine or the 24VAC control
voltage side.

CAUTION:

Drain lines must be as specified on installation drawings.

Drain line should be properly vented and should have

fall of not less than 1/4” to the foot of proper flow.

Some area plumbing codes require drains

to flow into an open gap with an opening twice the

diameter of the pipe.

Check with your local plumbing codes for the type of

drain connection required.

Mechanical Connections
Connect water lines for tank fills as tagged and
noted on the installation drawings.

If machine is provided with steam heat connect the
steam lines and steam condensate lines as tagged
and noted on installation drawings. If machine is
provided with gas heat, connect the gas line.

If a booster is provided a hot water connection is
necessary (110º F or 140º F).

PART 2 INSTALLATION INSTRUCTIONS

CAUTION:

All lines must be flushed prior to use to remove debris.

CAUTION:

Do not reduce the size of lines as specified in

installation drawings. All lines are sized to facilitate

necessary flows, pressures, etc.

CAUTION:

When connecting on the 24VAC control voltage side

of the transformer, total VA

must not exceed 5Kva.

Tabling
Load and unload tables should be pitched towards
the machine to return excess water into the machine.

CAUTION:

Machines with unload tables less than 48” should utilize

a rack limit switch to shut the machine down if clean

racks pile-up. This extends the life of the drive system.

HVAC
The ventilation system should be sized to provide
adequate ventilation per machine specs. Refer to
spec sheet.

Stainless steel, watertight ducting should be con-
nected to the vent cowls (optional) on each end of
the machine.

The detergent density probe can be placed in the
provided hole (labeled “Detergent Probe”) in the
wash tank.

Admiral Series DOC ADM-ES 1.0 04

www.insingermachine.com 800-344-4802

14