Insinger Admiral 44-4 User Manual

Page 19

Advertising
background image

DAILY CLEANING PROCEDURES

1. Remove all internal removable parts including

spray manifolds, scrap screens, drain overflow
tubes, suction strainers and curtains.

2. Remove the end caps from the spray manifolds

and clean with the brush provided. Flush the
manifolds.

3. Flush scrap screens.

4. Clean drain overflow tube.

PART 4 CLEANING INSTRUCTIONS

þ

NOTE:

Improper cleaning of the suction strainers will
cause the pumps to cavitate. This will cause
poor washing results.

5. Clean the suction strainers of build-up.

6. Clean the tank level float with a plastic abrasive

pad (do not use steel wool).

7. Clean curtains. When the curtains are beyond

cleaning or torn they should be replaced.

8. Clean final rinse nozzles of matter clogging the

jet spray.

9. Leave the doors open to allow the drying of the

interior surfaces.

The following cleaning procedures should be done daily, at the end of the shift.

WEEKLY CLEANING PROCEDURES

An ENERGY SAVER SWITCH is provided on the
control panel. When running the machine with
de-liming solution, place this switch in the OFF
position to allow the machine to run continuously.
When not de-liming, the switch should be in
NORMAL. Consult your detergent supplier for de-
liming solution concentration and frequency of use.

þ

NOTE:

V-cup seal on the drain overflow tube may
become gummed not allowing the overflow
tube to seal. This will cause the drain to leak
water. Remove any build-up on the V-cup
seal. When the seal becomes worn, replace
with part # D2-557.

þ

NOTE:

Level floats must be cleaned daily. Build-up of
grease and dirt will cause faulty operation of
the tank fill heating system.

The LIQUID LEVEL FLOAT is located below the
scrap screens in those tanks which contain water
heating devices (coils, steam injectors, or electric
immersion heaters) and pump inlet strainers. They
are usually located, in rackless and rack conveyor
style machines, on the inside tank wall, at approxi-
mately water level, opposite and parallel to the in-
spection doors. In the door, stationary rack type
machines, the LIQUID LEVEL FLOAT may be
found beneath the scrap screen.

Admiral Series DOC ADM-ES 1.0 04

www.insingermachine.com 800-344-4802

17

Advertising
This manual is related to the following products: