Troubleshooting

Troubleshooting for problems other than what is listed below should be performed by a qualified service person.
Troubleshooting performed by untrained personnel could result in electrical shock or damage to the disposer.
Disconnect power before servicing.

PROBLEM

POSSIBLE CAUSE

SOLUTION

Disposer will not start.

• No electrical supply.

• Disposer overload protector

is tripped.

• Disposer is jammed.

• Turn on electrical supply.

• Turn control to off position and press red reset button

on disposer.

• Turn control to off position and complete

following steps:

1. Insert one end of self-service wrenchette into center

hole on bottom of disposer. Work wrenchette back
and forth until it turns one full revolution. Remove
wrenchette.

2. Reach into disposer with tongs and remove object(s).

Allow disposer motor to cool for 3-5 minutes, then
lightly push red reset button on disposer bottom. (If
motor remains inoperative, check service panel for
tripped circuit breakers or blown fuses.)

Disposer motor stops while
grinding.

• Disposer is jammed.

• Disposer overload protector

is tripped.

• See "Disposer is jammed," above.

• Turn control to off position and press red reset button on

disposer. If disposer was running, allow unit to cool 3-5
minutes before pressing red reset button. Never strike
reset button with objects.

Overload protector
trips frequently.

• Disposer is overloaded with

food waste.

• Do not overload disposer with excessive amounts of

food waste.