3 introduction to the operation "firing – Ivoclar Vivadent EP 600 Combi User Manual

Page 20

Advertising
background image

Please use only the original
standard programs, which are
especially coordinated with the
corresponding materials for the
Ivoclar Vivadent all-ceramic
systems (IPS

e.max

, IPS Empress

System).

20

Freely programmable press programs
Furthermore, the EP600 Combi is equipped
with 4 freely programmable press programs
(P8–P11). For these programs, values within
the following ranges can be entered:

Important information
For the layering technique, we
recommend a stop speed of
300 mm/min, for the staining
technique 150 mm/min.

Higher values (stop speed of e.g.
300 mm/min) results in the press cycle
being stopped sooner.

Lower values (stop speed of e.g.
100 mm/min) results in the press cycle
being stopped later. Consequently, the
press cycle is prolonged.

Once the program is started by pressing
START, the new program is displayed in the
usual manner.

5.3 Introduction to the

operation "Firing"

5.3.1 Main menu "Firing"
The main menu "Firing" always displays
menu items, which may be selected by
means of the function keys F1, F2, and F3.
The menu comprises several pages. F4 is
used to move forward.

Menu without program memory card in
place:

Page 1

Menu with program memory card in place:

Page 1

Page 2

Parameter

B Stand-by temperature

t Temperature increase

T Holding temperature

H Holding time

E Stop speed

MIN

50

1

50

0

0

MAX

900

140

1200

109

1000

Unit of measure

°C

°C/min.

°C

min.

µm/min

Advertising