8.1

Cables

Check the condition of welding and connection cables daily. Do not use faulty cables!
Make sure that the mains connection cables in use are safe and according to regulations!
The repair and mounting of mains connection cables should be carried out only by an

authorized electrician.

8.2

pOwer sOurCe

NOTE!

Disconnect the plug of the power source from the mains socket before removing the cover

plate.
Check at least every 6 months (twice a year):

• Electric connections of the unit - clean the oxidized parts and tighten the loosened ones.

• NOTE! You must know correct tension torques before starting the repair of the joints.

• Clean the inner parts of the machine from dust and dirt e.g. with soft brush and vacuum

cleaner.

• Do not use compressed air. Do not use pressure washing device!

• There is a risk that dirt is packed even more tightly into gaps of components!

• Only authorized electrician shall carry out repairs to the machines.

8.3

dispOsal OF the maChine

Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical and electronic

equipment, and its implementation in accordance with national law, electrical equipment

that has reached the end of its life must be collected separately and taken to an appropriate

environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional

collection centre, per the instructions of local authorities or a Kemppi representative. By

applying this European Directive you will improve the environment and human health.