not recommended for users with beard or long hair extending to the

respiratory zone.

• Beware of a higher CO concentration in the air supply, which may

occur if the compressor does not work properly when lubricating oil

burns due to high temperatures.

• The supply air pressure must be within the range 300 – 1000 kPa.

• The supply pressure hoses may only be located in such places of the

workplace where they cannot be damaged.

• The maximum working pressure of the hose supplied to the

conditioner is 1000 kPa.

• Before connecting the unit to the air distribution, it is necessary to

check what medium is in the line and what is its quality. For the FA

Pressure units, it is necessary to provide breathable air according to

EN 12 021 standard.

• The FA Pressure unit can be combined with Beta 90 FreshAir or Delta

90 FreshAir head tops.

• Information on head parts are provided in the instructions for use of

the FreshAir head parts.

FA Pressure Conditioner

• Pressure hose for FA Pressure Conditioner is not antistatic and the

maximum temperature to which they are resistant without damage is

70 °C.

• The maximum length of the hose from the compressed air distribution

or FA Pressure Conditioner to the head unit must not exceed 10 m.

• The recommended temperature range of use ideally is 10 – 40 °C. At

lower temperatures, the use of the protective hood with air supply

may be unpleasant. The lowest allowable temperature for use of FA

Pressure is 10 °C.

NOTE! If the recommendations stated in this manual are ignored, the warranty

is automatically invalidated and the level of personal protection may not meet

the designated standards.