En 4. usage, 1 inspection before every use, 2 air flow test – Kemppi FreshAir Pressure Flow Control unit User Manual

Page 9

Advertising
background image

EN

4.

USAGE

4.1

Inspection before every use

Do the following checks always before you start using the equipment:

• Visually check individual parts, particularly the air hose and sealing

elements for damages.

• Check that the hose is fitted correctly to the air unit and to the head

part connector.

• The air pressure in the distribution system must be in the range

300 – 1000 kPa.

• Check that the air flow in the hose is sufficient.

• Ensure that air is supplied into the head part breathing zone.

4.2

Air flow test

When measuring the air flow, follow the instructions delivered with the flow

indicator. If the flow rate is different, proceed as follows.

1.

Pull plastic screw cap out to the adjustment position and turn counter-

clockwise by hand until it stops.

2.

Lever the cap off from the regulation valve with a flat screwdriver.

9

© Kemppi Oy / 1309

Advertising