Assembly – Koga Performance line - E-lement 2015 E-XLR8 User Manual

Page 18

Advertising
background image

English–10

Bosch eBike Systems

0 276 001 SPI | (16.7.14)

Technical Data

Assembly

Place down the battery pack only on clean surfaces.

In particular, avoid soiling the charge socket and the con-

tacts, e.g. by means of sand or soil.

Checking the Battery Pack
Before Using for the First Time

Check the battery pack before charging it or using it with your

eBike for the first time.
For this, press the On/Off button A4 to switch on the battery

pack. When no LED of the charge-control indicator A3 lights

up, the battery pack may be damaged.
When at least one, but not all LEDs of the charge-control indi-

cator A3 is lit, then fully charge the battery pack before using

for the first time.
Do not attempt to charge or use a damaged battery

pack.

Please refer to an authorised Bosch eBike dealer.

Charging the Battery Pack

Use only the Bosch charger provided with your eBike or

an identical original Bosch charger.

Only this charger is

matched to the lithium-ion battery pack used in your eBike.

Note:

The battery pack is supplied partially charged. To en-

sure full battery pack capacity, completely charge the battery

pack in the charger before using for the first time.
For charging the battery pack, read and observe the operating

instructions of the charger.

The battery pack can be recharged at any time on its own or on

the bike without shortening the lifespan. Interrupting the

charging process does not damage the battery pack.
The battery pack is equipped with a temperature control indi-

cator, which enables charging only within a temperature

range between 0 °C and 40 °C.

When the battery pack is not

within the charging-tempera-

ture range, three LEDs of the

charge-control indicator A3

flash. Disconnect the battery pack from the charger until its

temperature has adjusted.
Do not connect the battery pack to the charger until it has

reached the allowable charging temperature.

Charge-control Indicator
When the battery pack is switched on, the five green LEDs of

the charge-control indicator A3 indicate the charge condition

of the battery pack.
In this, each LED indicates approx. 20 % capacity. When the

battery pack is completely charged, all five LEDs light up.
The charge level of the switched on battery pack is also shown

on the display of the on-board computer. When doing so, read

and observe the operating instructions of the drive unit and

on-board computer.
If the capacity of the battery pack is below 5 %, all LEDs of the

charge-control indicator A3 on the battery pack go out. Howev-

er there is another display function of the on-board computer.

Lithium ion battery pack

PowerPack 300

PowerPack 400

Article number

– Standard battery pack

– Rack-type battery pack

0 275 007 509

0 275 007 511

0 275 007 513

0 275 007 510

0 275 007 512

0 275 007 514

0 275 007 522

Rated voltage

V=

36

36

Rated capacity

Ah

8.2

11

Energy

Wh

300

400

Operating temperature

°C

–10...+40

–10...+40

Storage temperature

°C

–10...+60

–10...+60

Allowable charging temperature range

°C

0...+40

0...+40

Weight, approx.

kg

2.0/2.4

2.5/2.6

Degree of protection

IP 54 (dust and splash

water protected)

IP 54 (dust and splash

water protected)

OBJ_BUCH-2087-002.book Page 10 Wednesday, July 16, 2014 5:12 PM