A-chain alignment procedures – Dolby Laboratories CP65 User Manual

Page 31

Advertising
background image

A-Chain Alignment Procedures

Step

No.

4-8

Indication

Action

b. Optical Preamplifier Adjustments

Mono

01

format

Mono

01

format

4

5

6

Dolby

Rt

Lt

Lt

Rt

gnd

Proj. 2

hf

GAIN

hf

GAIN

Rt tp

Rt

Lt

Lt tp

Proj. 1

hf

GAIN

hf

GAIN

signal

present

Cat. No.

240A

Cat. No. 240A

X

Y

Proj. 1 Status

RV101 Gain
RV102 hf
RV201 Gain

RV202 hf

TP501 L tp

TP502 R tp

R

L

RV301 Gain

RV302 hf
RV401 Gain
RV402 hf

Proj. 2 Status

TP503 GND

R

R

L

L

SIGNAL
PRESENT

RTA

SCOPE

DUAL TRACE
MODE

IN

NOTE: Be sure that the vertical

range is set the same on
both channels.

A-Chain Alignment Procedures

Notes

4-9

b. Optical Preamplifier Adjustments

On the Cat. No. 240A Optical Preamplifier Card

Turn all of the Proj 1 and Proj 2 hf potentiometers fully counterclockwise (CCW).

Verify that power to the power amplifiers is OFF.

Press the Mono 01 format switch on the front panel; the LED in the switch should light.

Connect the RTA and the oscilloscope to the Cat. No. 240A TP501 L (left) and TP502 R
(right) test points as shown in the interconnection diagram. Switch the scope to dual trace
mode.

Earth (ground) both instruments at TP503 GND on the card.

The input to the RTA will be switched to the left channel or right channel in the following
steps.