Dolby Laboratories CP65 User Manual

Page 38

Advertising
background image

Magnetic Alignment

c. Magnetic Preamplifier Adjustments

7. Remove the Cat. No. 242 card and locate the reversible plug-in Magnetic Input

Sensitivity header.

100mV

in

1V in

The CP65 accepts a nominal operating input level of either 100 mV or 1V — chosen
by the position of the reversible plug-in header. The input impedance of the CP65
is 100K at both input levels. In addition, some preamplifiers may require a
termination resistor (usually 600 ohms). You can connect the termination resistors
at the input barrier strip TB3 and TB4 "from mpu–no nr" terminals on the backplane.
Note that changeover between projector 1 and projector 2 must be accomplished
in the magnetic preamplifier.

If noise reduction is to be used for decoding 70 mm Dolby Stereo soundtracks,
the header on the Cat. No. 242 B-chain card must be set to the 100 mV position.

If the existing non-Dolby magnetic preamplifiers are used, their compatibility with the
CP65 must be ensured.

8. Re-install the Cat. No. 242 card and restore the NORMAL/BYPASS switch to the

NORMAL position.

A-Chain Alignment Procedures

4-21

Advertising