INSTALLATION OF TLMC-W CALL STATION
Model TLMC-W is designed for mounting to a wall or flat surface. Included are two backboxes:

Lift and separate plastic backbox from metal backbox

1) SURFACE MOUNTING BACKBOX TO WALL

a. Metal backbox has 4 mounting holes for securing to wall

(screws not supplied).
b. Drill an opening at top, bottom, side or back of backbox for passing
wiring or connecting conduit.
c. Six small screws are supplied for attaching TLMC-W face plate to backbox.

2) FLUSH MOUNTING BACKBOX TO WALL

a. If plastic flush mount backbox is to be used:

b. Drill an opening at back side, as needed, to secure plastic backbox to proper position in wall

opening.

c. Drill an opening at a convenient location on backbox for passing wire or for conduit

connection (top, bottom, etc.)

d. Six plastic anchor bolts are supplied for securing TLMC-W face plate to backbox.

White plastic backbox is for flush mount
Beige metal backbox is for surface mount

(2) backboxes

plastic

backbox

metal

backbox

Page 5 of 8

LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406

TEL (818) 994-6498

FAX

994-6458

website: www.louroe.com e-mail: [email protected]

(818)

®

INSTALLATION AND OPERATING INSTRUCTIONS

tlmc_w_inst_3/15

Advertising