SENSITIVITY SWITCH OF MICROPHONE

For special installations that require less microphone sensitivity, a sensitivity switch has been added
to the microphone pre-amp (PC board) and has two positions - N and L:

N represents normal sensitivity (0dB output into 1KW

)

L represents low sensitivity (-6dB output into 1 KW

)

NOTE: Louroe Verifact microphones are always shipped with the sensitivity switch in

normal (N) position. Do not change unless required.

Should an adjustment be necessary, locate the small red switch on the PC board mounted behind the
back side of the stainless face plate. Using a small tool, move the slide switch from N to L

SPECIFICATIONS

Sensitivity

-45 dB

Line Level (0 dBV, 600

W

@ 1kHZ)

Frequency response

50 Hz to 15 kHz

Output

Current drain

10 mA

DCS-1 DURESS CALL STATION

Page 3 of 4

LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406

TEL (818) 994-6498

FAX

994-6458

website: www.louroe.com e-mail: [email protected]

(818)

®

INSTALLATION AND OPERATING INSTRUCTIONS

Tone output

3 Vrms into 10K
load @ 3 kHz

Supply voltage

12 Vdc

Dimensions

Weight
Shipping Weight

4 1/2“ L x 2 3/4“ W

4 oz
1 lb