In the High-speed, single-channel (burst mode), all ChartView display functions are
intentionally disabled. Data acquisition and storage to disk are the only services that remain
functional. When you select the High-speed, single channel mode, a Warning dialog box
appears with this information, providing you with the opportunity to cancel if desired.

Reference Note: Burst mode operational constraints are discussed in greater detail on page CV-43.

Acquisition Setup

Parameter

Options

Event Configuration

Trigger: Set a trigger scan in the Acquisition by using one of the following:

Keyboard - Use Console Trigger dialog box to start trigger scan.

Note: If the Keyboard Trigger is selected the use of Pre-trigger is disabled.

External TTL - Use an external signal to start the trigger scan.

Channel Value - Use specified value and or hysterisis of a given channel. Select if the
trigger is to occur “above” or “below” the specified values.

Alarm - Use an Alarm value to start the trigger scan.

Absolute Time - Use a time of day to start the trigger scan.

Note: If Absolute Time is selected, the use of Auto Re-Arm is disabled.


Stop:

Set a stop scan in the Acquisition by using one of the above selections or Count (as
specified below). Keyboard isn’t applicable. If a MultiScan, ChartScan, or NetScan is
connected and High-Speed Single-Channel (Burst Mode) is selected, then “Count from
trigger” is the only Stop available for the event configuration.


Count: Specify a number of scans to be read before a stop scan is set.

Acquisition

Parameters

Scan Counts:

Specify the number of scans in an acquisition

Pre-trigger

Post

Stop

Average weight: Average weight can be specified only when in the Normal Mode. The value for

the average weight determines the number of samples to be averaged when in
Normal Mode. Values of 1, 2, 4, and 8 are for high-speed multiple channel
applications for thermocouples and DC voltages where noise filtering is not an
issue.
Values of 16, 32, 64, 128, and 256 are recommended for AC noise rejection.

Scan Intervals: Time between scans (frequency of scans)

Pre-trigger and Post Stop

Post-trigger

Use one Interval

High Speed Setup:

Allows for channel and scan rate entries for high-speed, single channel mode.

Note: These parameters cannot be altered while an acquisition is in progress.
Note: If Normal Mode is selected, channels assigned to a chart must be (and will be) enabled in the Acquisition.