Technical specifications tcr511 – Meinberg TCR511 User Manual

Page 18

Advertising
background image

18

Technical Specifications TCR511

RECEIVER INPUT:

AM INPUT ( SMB-Connector ) :
insulated by transformer
impedance :

50

Ω, 600 Ω, 5 kΩ

selectable by jumper

input signal :

abt.600mVpp to 8V (Mark)

other ranges on request

DC-Level Shift Input ( VG-Connector )
insulated by opto-coupler device
internal series resistor : 330

max. input current:

25mA

diode forward voltage : 1.0V...1.3V

DECODING:

decoding of the following codes possible :
IRIG-A133/A132/A003/A002
IRIG-B123/B122/B003/B002
AFNOR NFS 87-500

ACCURACY OF TIME BASE : +/- 10us compared to IRIG reference marker

REQUIRED ACCURACY OF
TIME CODE SOURCE :

+/- 100ppm

HOLDOVER MODE:

automatic switching to crystal time base,
accuracy : see. accuracy of Oscillator

BACKUP BATTERY :

onboard realtime clock keeps time and date
in case of power supply failure. System parameters
are stored in battery buffered ram
lifetime of Lithium battery at least 10 years

RELIABILITY OF
OPERATION:

microprocessor supervisory circuit generates reset
in case of brown-out, software watchdog generates
reset in case of improper program execution

INITIALIZATION:

initial time and date can be set by standard
meinberg telegram via serial port COM0

PULSE OUTPUTS:

pulse per second PPS,
TTL-Level pulse, active high, 200ms pulse width
pulse per minute PPM,
TTL-Level pulse, active high, 200ms pulse width