Format of the Uni Erlangen String (NTP)

The time string Uni Erlangen (NTP) of a GPS-clock is a sequence of 68 ASCII
characters starting with the STX (start-of-text) character and ending with the ETX (end-
of-text) character. The format is:

<STX>tt.mm.jj; w; hh:mm:ss; voo:oo; acdfg i; bbb.bbbbn llll.lllle hhhhm<ETX>

The letters printed in italics are replaced by ASCII numbers whereas the other characters
are part of the time string. The groups of characters as defined below:

<STX>

Start-Of-Text (ASCII code 02h)

dd.mm.yy the current date:

dd

day of month

(01..31)

mm month

(01..12)

yy

year of the century

(00..99)

w

the day of the week

(1..7, 1 = Monday)

hh.mm.ss

the current time:

hh

hours

(00..23)

mm minutes

(00..59)

ss

seconds

(00..59, or 60 while leap second)

v

sign of the offset of local timezone related to UTC

oo:oo

offset of local timezone related to UTC in hours and minutes

ac

clock status characters:

a:

‘#’ clock has not synchronized after reset
‘ ‘ (space, 20h) clock has synchronized after reset

c:

‘*’ GPS receiver has not checked its position
‘ ‘ (space, 20h) GPS receiver has determined its position

d

time zone indicator:

‘S’

MESZ European Summertime, daylight saving enabled

‘ ‘

MEZ

European Standard Time, daylight saving disabled

f

anouncement of discontinuity of time, enabled during last hour
before discontinuity comes in effect:

‘!’

announcement of start or end of daylight saving time

‘ ‘

(space, 20h) nothing announced