11

Framing

Lever 4 of the DIL switches is used to select the framing of the serial ports. Changes in
these settings become valid after reset. Other framings on request.

SWx-4

Framing

off

7E2

on

8N1

Time Zone

Levers 7 and 8 of the DIL switches let the user select a time zone (MEZ/MESZ, UTC,
MEZ) for each channel. The front panel display always shows the time zone selected
for COM0.

SWx-7

SWx-8

Time Zone

off

off

MEZ/MESZ = CET/CEST

off

on

always MEZ=CET

on

off

UTC

on

on

(reserved)

Output mode

Both of the serial ports send a time string in three different output modes.

SWx-5

SWx-6

String Mode

off

off

on request only

on

off

once per second

off

on

once per minute

on

on

(reserved)

1. on request only:

output of the time string starts 2ms after sending a
"

?

" (ASCII-Code 3Fh) to the clock

2. once per second:

output of the time string starts whenever a new
second begins

3. once per minute:

output of the time string starts whenever a new
minute begins