Technical specifications – Meinberg DCF77 UA509 User Manual

Page 14

Advertising
background image

14

Technical Specifications

RECEIVER:

Direct conversion quadrature receiver with automatic gain
control
Bandwidth: approx. 20Hz

DISPLAY:

eight digit 7-segment display, 2.5mm character height
shows either time or date, selectable by front-panel switch
LEDs for modulation, field strenght and free running

TIMECODE
CHECK:

multiple software check of the incoming timecode
parity and consistency check over a period of two minutes

RUNNING
ON XTAL:

RF distortions indicated by "Freil."-LED and a status character
in the serial output string
without RF signal the clock runs on XTAL with an accuracy
of 10

-6

(after 24 hours of synchronous operation)

BUFFERING:

In case of supply voltage failure the on-board RTC keeps the
time based on XTAL for more than 150 hours (buffer capacitor)
optional lithium backup battery (life time: 10 years)

RELIABILITY
OF OPERATION: A software watchdog lets the microprocessor recover from

malfunction. A power-fail comparator resets the microproces-
sor if the supply voltage drops below a specified threshold.

MANUAL
TIME SETTING:

Two optional push buttons provide manual setting of time and
date.

PULSE OUTPUTS: active high and active low TTL output lines provide pulses per

second and per minute with 200ms of lenght

INTERFACES:

2 independent interfaces (COM0 and COM1)
baudrate, framing, output mode and time zone are configurable
for each interface

COM0:

2 active and 2 passive 20mA current loop outputs
1 active/passive 20mA current loop input
1 RS232 output, 1 RS232 input
RTS and CTS handshake signals

COM1:

1 active and 1 passive 20mA current loop outputs
1 active/passive 20mA current loop input
1 RS232 output, 1 RS232 input
RTS and CTS handshake signals