Operating heater – Design Dynamics VTD-18N-PDG User Manual

Page 11

Advertising
background image

www.desatech.com

111826-02J

11

OPERAtING HEAtER

Continued

5. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information, page10. If you don’t

smell gas, go to the next step.

6. Press in and turn control knob counter-

clockwise

to the PILOT position.

Press in control knob for five (5) seconds

(see Figure 11).

Note: You may be running this heater for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

7. With control knob pressed in, press ignitor

button. This will light pilot. The pilot is at-

tached to the front burner. If needed, keep

pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure.

8. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop out when

released, contact a qualified service person

or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4

through 8.

9. Slightly push in and turn control knob coun-

terclockwise

to the ON position.

10. Wait one minute and switch selector switch

to the ON position to light burners.

11. Set flame adjustment knob to any level

between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Figure 11 - Control Knob and Ignitor

Button Locations

LO

IH

OF

F

PILOT ON

AUTO

OFF

ON

Control Knob

Ignitor Button

Flame Adjustment Knob

Selector Switch

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation

of new heater, burning logs will

give off a paper-burning smell.

Orange flame will also be pres-

ent. Open damper or window to

vent smell. This will only last a

few hours.

WARNING: Damper handle

will be hot if appliance has been

running.

CAUTION: A mild gas flash

within 10 seconds is normal

during shutdown of this heater.

Remain clear of the hearth area

for the entire shutdown process

to avoid possible injury.

NOTICE: During initial operation

of new heater, metallic compo-

nents may emit an odor as paint

and assembly compounds are

heated and cure. Be sure to pro-

vide adequate fresh air if odors

are detected.

1. STOP! Read the safety information on

page 10.

2. Make sure equipment shutoff valve is fully

open.

3. Set selector switch in the OFF position.

4. Turn motor knob clockwise

to the

OFF position.

WARNING: Burners will

come on automatically within

one minute when the selector

switch is in the ON position after

the pilot is lit.