Installation – Design Dynamics VTD-18N-PDG User Manual

Page 7

Advertising
background image

www.desatech.com

111826-02J

7

INStALLAtION

Continued

Damper
Clamp

Damper

Damper

Damper
Clamp

Masonry Fireplace

Manufactured

Fireplace

Figure 4 - Attaching Damper Clamp

The minimum flue sizes shown in Figure 3, page

6, are based on a 6' chimney height using round

pipe. Your minimum flue size will vary based

on input rate and chimney height. Refer to the

National Fuel Gas Code ANSI Z223.1/NFPA 54,

Section 6.6 for details.

INSTALLING DAMPER CLAMP

Secure damper stop clamp to edge of damper as

shown in Figure 4. I for any reason this clamp

doesn't work on your fireplace, another suitable

clamp or permanent stop must be installed or

damper blade must be removed.

INSTALLING HEATER ASSEMBLY

CAUTION: Do not remove the

data plates attached to the heater

base assembly. The data plates

contain important warranty and

safety information.

WARNING: If installing in a

sunken fireplace, special care

is needed. You must raise the

fireplace floor to allow access to

heater control panel. This will in-

sure adequate air flow and guard

against sooting and controls be-

ing damaged. Raise fireplace floor

with noncombustible material.

Make sure material is secure.

CAUTION: Do not pick up

heater assembly by the logs. This

could damage heater. Only han-

dle base assembly by grates.

IMPORTANT:

Make sure appliance is level. If

heater is not level, heater will not work properly.
Installation Items Needed

• control cover kit (provided with heater)

• approved flexible gas hose (provided) (if al-

lowed by local codes)

• sealant (resistant to propane/LP gas, not

provided)

• pipe wrench
Note:

Install optional remote control accessories

(see Accessories, page 19) before installing gas

log heater.

1. Apply pipe joint sealant lightly to male threads

of gas fitting (not provided). Connect approved

flexible gas hose to inlet side of gas control (see

Figure 5). IMPORTANT: Hold gas fitting with

wrench when connecting flexible gas hose.

2. Position heater assembly in fireplace.

3. Connect to gas supply. See Connecting to

Gas Supply.

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 3/8" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified ser-

vice person must connect heater

to gas supply. Follow all local

codes.

Gas Control

Flexible
Gas Hose
(if allowed
by local
codes)

Figure 5 - Attaching Flexible Gas Hose to

Heater Gas Regulator

Advertising