Section 3-2-1: venting layout, Roof mounted terminations, Section 3-2 – Montigo H38DF PFC User Manual

Page 10: Installing a roof mounted direct vent, Installation

Advertising
background image

Page 10

XG0816 - 150204.1

H*38DF PFC Peninsula Gas Fireplace

Installation

Section 3-2:

INSTALLING A ROOF MOUNTED DIRECT VENT

TERMINATION (PVTK-1)
This section applies to installations where the direct vent termi-

nation will be roof mounted�

Section 3-2-1:

VENTING LAYOUT

Selection of components and details of venting lay out should

adhere to the following guidelines:

„

The maximum termination point is 32’ above the fireplace (NOTE:

if the maximum termination height is used, the flame pattern

may be affected).

„

The Vertical termination must be a minimum 2’ higher than

where the termination exits the roofing materials, (asphalt

shingles, cedar shakes, etc)� This distance should be measured

from the high side of the roof slope where the flue flashing

intersects the roofing materials. (see Figures 9 - 9c).

„

For a detailed diagram of allowed termination locations, see

Appendix A�

„

Termination location must be a minimum 6’ from a mechanical

air inlet.

„

A maximum of two offsets (each offset is made up of 2-90°

bends) may be made for vertical vent runs.

„

Firestops must be installed as required by National & local codes.

„

Ensure all horizontal runs are supported with a minimum of 3

supports per 10’ of venting.

„

Install all roof flashing and storm collars as shown.

Figure 9. Top vent, Roof mounted termination with no offset in vent run.

Figure 9a� Top vent, Roof mounted with 1 offset (1 offset= two 90° bends).

Figure 9b� Top vent, Roof mounted with 2 offsets (1 offset= two 90° bends).

Roof mounted Terminations

The following details are some possible configurations for Roof

mounted terminations.

Support ring

Support plate

Firestop

32’ max.

2’ min.

PVTK1

Termination

Support straps or

support plate & ring

2’ min.

Firestop

Firestop

Firestop

32’ max

Support plate

& ring

Obstacle

PVTK1

Termination

Support ring

Support plate

Firestop

32’ max.

2’ min.

Obstacle

PVTK1

Termination