Section 2: framing, Installation – Montigo H38DF PFC User Manual

Page 7

Advertising
background image

Page 7

XG0816 - 150204.1

H*38DF PFC Peninsula Gas Fireplace

Installation

Section 2: Framing

Note: Images are shown without screens for clarity purposes. However,

your fireplace should not be operated without proper installation of

screens.

1).

Frame in the enclosure for the unit with framing materials. The

framed opening for the assembled fireplace is 23 3/4" wide, x 44"

high x 41" deep, see Figure 2

.

NOTE: When constructing the framed opening, please ensure there is

access to install the gas line when the unit is installed. See Figure 21

Figure 2� Framing dimensions.

Figure 3� Combustible Framing for shelves over the fireplace, Rear vent.

Figure 5� Non Combustible Framing with alcove above fireplace, Top Vent.

41

23 3/4

44

Figure 4� Combustible Framing for shelves over the fireplace, Top vent.

11”

Min.

Combustible Shelf

33”

44”

Exterior

Wall

Combustible Header

12” Max.

4” Nailing flange

or Non-combustible

material.

46” Min

17 1/2”

2” Min.

44”

Combustible Shelf

Combustible Header

Min.

Exterior

Wall

PEL Short

90 elbow

4” Nailing flange

or Non-combustible

material.

58” Min for HP

Floor

39 5/8”

44”

Combustible

Header

Min. 1 ”

2”

Ceiling level

Non-Combustible

Header

Non-Combustible

materials. Alcove

over fireplace.

Top Vent

Non-Combustible

Materials, with Low

profile mantel / Alcove

over fireplace.

84”

min.