Installation, Optional fan kit, Operation – Montigo RFK3002 User Manual

Page 2: General information

Advertising
background image

Installation

Page 2

XT0018 - 150324

Figure 3

Accessing control compartment.

Figure 4

Cutaway view of control compartment showing fan

motor installation.

Figure 5

Installing the PPO Box.

2. Fan Motor Installation

• Install each fan motor with the blades facing the 4" round fan

opening. Attach the mounting legs by screwing into the pilot

holes around the fan opening. Spin the fan blades by hand

to ensure they don't hit the fan opening. (See Figure 4.)

3. Installing the Power Box (only for B34DV2, B38DV2)

• The PPO box connects the fans to the household electrical

supply. In some models this box has been factory-installed,

and is located at the bottom right corner of the fireplace.

• If the PPO box has not been factory installed, ensure that

the household electrical supply is shutoff at the breaker or

fuse, and connect the two wire leads from the box to the

household electrical supply. Insert the PPO box into the

square hole in the right-hand side of the control compartment

and screw into place using self drilling hex screws as shown

in Figure 5, 6 and 7.

Optional Fan Kit

Optional Fan Kits

Installing the Power Box

The PPO box connects the fans to the household electrical supply.
In some models this box has been factory-installed, and is located
at the bottom right corner of the fireplace.
If the PPO box has not been factory installed,

ensure that the

household electrical supply is shutoff at the breaker or

fuse, and connect the two wire leads from the box to the
household electrical supply. Insert the PPO box into the square hole
in the right-hand side of the control compartment and screw into
place as shown in Figure 4.
Plug the wire harness' power cord into thePPO box.

Figure 4. Installing the PPO box.

PPO box

To electrical

supply

Heat sensor

locator screw

Attaching the Heat Sensor

Some kits include the optional heat sensor for automatic
control of the fans. Mount the sensor on the bottom right
side of burner panbase. Remove the two screws located
on the top of the control compartment, just to the right of
the gas control valve. Attach the heat sensor by screwing
the mounting bracket into place using the two screws.

Figure 5. Installing the heat sensor.

Page 2 of 2

XG0630 - Rev. 04/99

Operation

1. Turn on electrical power at the breaker or fuse.
2. If the fans are

manually controlled (not connected to a heat

sensor), turn on the fans' wall switch to activate the fans.
To stop the fans, turn off the wall switch.

3. If the fans are

heat-activated, they will automatically switch

after the fireplace's main burner has been lit and the
temperature has risen. The time lapse between lighting the
fireplace and fan activation will vary, depending on the model.
The fans will automatically shut off as the fireplace cools.

Heat sensor

Power cord

Optional Fan Kits

Optional Fan Kit

General Information

KIT #

Description

Models Used With:

RFK1002 2 fan kit, manual control

B34-DV, B34-DV-2
C34-DV, C34-VF

RFK1003 2 fan kit, heat-activated control

B34-DV, B34-DV-2
C34-DV, C34-VF
C38-DV

RFK1006 4 fan kit, manual control

C38-DV, C42-DV

RFK1007 4 fan kit, heat-activated control

C38-DV, C42-DV

RFK1008 4 fan kit, manual control

M38DV-ST

RFK1009 4 fan kit, heat-activated control

M38DV-ST

Before You Begin

„

Please read all instructions carefully.

„

We strongly recommend that all electrical service work be
performed by a qualified electrical contractor.

„

Check to ensure that all components required for installation
are included in your package.

Pull trim outwards
from bottom

Trim

Retainer clip

Control compartment

Figure 1. Removing the lower horizontal trims.

Installation

Accessing the Control Compartment

„

Remove the lower horizontal trims by placing your fingers under
bottom edge of trim next to retainer clips and pull outward. (See
Inset, Figure 1.)

„

Install each fan motor with the blades facing the 4" round fan
opening. Attach the mounting legs by screwing into the pilot holes
around the fan opening. Spin the fan blades by hand to ensure
they don't hit the fan opening. (See Figure 2.)

Fan Motor Installation

Figure 2. Cutaway view of control compartment showing fan
motor installation.

Pilot Holes

Mounting Legs

Access for

electrical connections

wire harness connector

fan motor
connector

Electrical Connections

„

Plug each of the fan motor connectors into a quick connector on
the wire harness. See Figure 3.

115/1/60 Supply

G

L1 L2

Figure 3. Electrical Connections.

XG0630 - Rev. 05/99

Page 1 of 2

Installation

1. Accessing the Control Compartment

• Flip down the lower horizontal trims of the

fireplace Figure 3.)

Lower horizontal trim

Figure 1. Removing the lower horizontal trims.

Inset, Figure 1.)

Figure 6

Installing the PPO Box (from outside of fireplace).

Figure 7

Lead wires that connect to household electrical

supply.

Advertising