background image

Installation

Page 4

XT0018 - 150324

Wiring for the

optional Fan Kit

All

B-Series DV-2 fireplaces may be equipped with optional fan kits

for circulating heat into the living space.
Installations in Canada which employ the fans must be electrically

grounded in accordance with

CSA C22.1 Canadian Electrical Code

Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded

in accordance with local codes or, in the absence of local codes, with
the National Electrical Code,

ANSI/NFPA 70-1987.

NOTE: If any of the original wire supplied with the appliance is replaced, it

must be replaced with the same type, or its equivalent.

115/1/60 Supply

G

L1 L2

G

L2-WH

L1-BLK

Quick Connect

plug to motor

Figure 11. Wiring schematic for optional fans.