Installation, Wiring for the optional fan kit – Montigo RFK3002 User Manual
Page 4
Installation
Page 4
XT0018 - 150324
Wiring for the
optional Fan Kit
All
B-Series DV-2 fireplaces may be equipped with optional fan kits
for circulating heat into the living space.
Installations in Canada which employ the fans must be electrically
grounded in accordance with
CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded
in accordance with local codes or, in the absence of local codes, with
the National Electrical Code,
ANSI/NFPA 70-1987.
NOTE: If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
115/1/60 Supply
G
L1 L2
G
L2-WH
L1-BLK
Quick Connect
plug to motor
Figure 11. Wiring schematic for optional fans.