XG0518 - 070714

Figure 5h.

Step 8: Using the large bell connector, connect the white fiber wire

from the power cable to the black wire from the motor and the black

wire from the capacitor.

Figure 5i.

Step 9: Using the small bell connector, connect the brown wire from

the motor to the black wire from the capacitor.

Figure 5g.

Step 7: Strip all the wires for connection. Using old ground screw

secure the ground wire and new capacitor to the motor.

Figure 5f.

Step 6: Remove ground screw that secures the ground wire and

capacitor bracket to the motor. Note: Keep this screw for later use.

Dispose of old capacitor.

PVHEX58-300 & PVHEX510-300 Horizontal Power Vent