Service – Montigo PVHEX58-300 User Manual
Page 11
Advertising
Service
Page 11
XG0518 - 070714
Figure 5h.
Step 8: Using the large bell connector, connect the white fiber wire
from the power cable to the black wire from the motor and the black
wire from the capacitor.
Figure 5i.
Step 9: Using the small bell connector, connect the brown wire from
the motor to the black wire from the capacitor.
Figure 5g.
Step 7: Strip all the wires for connection. Using old ground screw
secure the ground wire and new capacitor to the motor.
Figure 5f.
Step 6: Remove ground screw that secures the ground wire and
capacitor bracket to the motor. Note: Keep this screw for later use.
Dispose of old capacitor.