Service

Page 15

XG0518 - 070714

Step 12: Using a supplied small bell connector, connect the black

fiber wire from the power cable to the blue wire from the motor.

Figure 6k.

Figure 6l.

Step 13: Using the supplied large bell connector, connect the white

fiber wire from the power cable to the black wire from the motor and

the black wire from the capacitor.

Figure 6j.

Step 11: Attach new capacitor and the ground wire to the ground on

the motor. Strip all the wire ends.

Figure 6i.

Step 10: Secure motor plate with supplied eight screws.

PVHEX58-300 & PVHEX510-300 Horizontal Power Vent