Montigo 36DRG User Manual

Page 4

Advertising
background image

Page 4 of 11

36DRG

09/96

5./ INSERT INSTALLATION

This appliance is to be installed in a masonary or slid
fuel fireplace only. (Not for use with air tight units.)
*Ensure that the plastic protective coating on the
all brass pieces is removed before lighting the
fireplace. Failure to do so will result in permanent
damage to the brass.

The brass louvres can be easily removed from the
outer box of the fireplace. We recommend that
they are removed to prevent any damage. The
louvres are held on with spring loaded pins.

1.) Remove the 2 glass panels from the unit to access
the heat exchanger {see section on glass panel re-
moval}.
2.) Detach burner tray by removing the two screws
located on either side of the tray. Pull tray slightly
towards the front of the unit and carefully pull
Burner out.
3.) Unscrew rheostat box and remove
4.) Detach decorative hood by removing the screws
located on each side.
5.) Remove the two screws at the top {left and right
side} of the heat exchanger. Pull heat exchanger,
including refractory, from the outer shell.
6.) Place the outer shell only into the masonary
fireplace. (See Drawing #3a)

DRAWING #3b

View of Heat
Exchanger
removed from
outer shell

Heat
Exchanger

Outer
Shell

DRAWING #4

Remove to pull out heat exchanger.

DRAWING #3a

Decorative Hood

Flex Liner

Flue Collar

7.) To connect the flexible gas liner, detach the

drafthood. Drop the flex liner down in to the
fireplace shell. Secure the flex liner to the flue
collar with a minimum of 2 sheet metal screws.

Advertising