6./ OPERATION
"For safety, this appliance has been equipped with
a high limit switch. In the event of over heating,
this switch will automatically turn the unit down to
pilot. Upon cooling, the main burner will re-light.
If this switch is activated, call a qualified service
person to inspect the fireplace."

A./ TESTING, ADJUSTING AND CHECKING
BURNER AND CONTROLS

Light burner by carefully following instructions for

starting given in this manual. Test and adjust all
controls under actual operating conditions and
in accordance with local installation codes for gas
bBurning appliances.

B./ PILOT BURNER ADJUSTMENT

1./ Remove pilot adjustment cap {see figure 10}
2./ Adjust pilot key to provide properly sized
flame {see figure 11}
3./ Replace pilot adjustment cap
4./ Leak test with soap solution after installing or
servicing with main burner on. Coat pipe and
tubing joints etc. with soap solution. Bubbles
indicate leaks. Tighten any areas where the
bubbles appear until the bubbling stops
completely.

C./ LIGHTING INSTRUCTIONS

The gas control valve is located behind the brass
trim at the base of the fireplace. Before lighting
the pilot, make sure that the gas line is connected
and the gas shut-off valve is turned to the ON
position.
a.)Be sure that the ON/OFF switch located on the
right side of the backplate is in the “OFF” position
b.) Partially depress and turn dial on gas control
Valve to “OFF” position and wait 5 minutes
c.) Turn dial to pilot position, depress dial and
light pilot using red Piezo ignitor button. Hold dial
for 1 minute, then release. If pilot does not remain
lit, repeat, allowing a longer time to lapse
before releasing dial.
d.) Once the pilot has been established, turn the
ON/OFF switch on the side of the backplate to the
"ON" position.
e.) To light the main burner, turn dial to “ON”
f.) Main burner function may now be controlled
with the ON/OFF switch on the side of the
backplate. “OFF” turns the unit back to pilot.
g.) The “HI/LO” dial located on the valve
manually controls the height of the flame on the
burner.

D./ SHUT DOWN INSTRUCTIONS:
a.) Turn knob to the “OFF” position to extinguish
main burner and pilot flame

7./ GENERAL MAINTENANCE

Installation and repairs should be done by a
qualified service person. It is recommended that
the appliance be inspected before use and at least
annually by a professional service person. More
frequent cleaning may be required due to excessive
lint from carpeting, bedding material etc. It is
imperative that control compartments, burners and
circulating air passageways of the fireplace
be kept clean. Any safety guards removed for
servicing this appliance must be replaced prior to
operating the appliance.

GAS CONTROL VALVE

1/8 N.P.T.
Pressure Tap

Pilot Adjustment
Cap

Power Pile

High Limit

On/Off Switch
on Backplate

PILOT BURNER ADJUSTMENT

3/8" to 1/2"

DRAWING #10