C34-VF Gas Fireplace

Part No. XG0316

Installing The Gas Line

The gas line must be installed before finishing the C34-VF Fireplace.

Natural gas requires a minimum inlet gas supply pressure of 5.5"

W.C. & a manifold pressure of 3.5" W.C. Propane gas requires a

minimum inlet gas supply pressure of 11" W.C. & a manifold pressure

of 10" W.C. Provision must also be made for a 1/8" N.P.T. plugged

tapping and be accessible for test gauge connection immediately

upstream of the gas supply controls to the appliance. The fireplace

gas connection and the main operating gas valve is located behind

the removable brass trim at the bottom of the unit and need only be

attached to the gas line with an approved fitting, as required by the

applicable installation codes.

Installation

Note: After gas line is connected, each appliance connection,

valve and valve train must be checked while under normal

operating pressure with either a liquid solution, or leak
detection device, to locate any source of leak. Tighten
any areas where bubbling appears or leak is detected until
bubbling stops completely or leak is no longer detected.
DO NOT use a flame of any kind to test for leaks.

Installing The Remote Switch

The C34-VF's gas valve, located behind the lower trim, may be

connected to a wall switch. The valve generates its own power on a

millivolt circuit. Use only low voltage wire, and DO NOt connect

any external power to it.
Refer to Figure 11 for wiring requirements.
Note: The switch location must not exceed 30' from the fireplace.

Figure 6.

Gas line access.

4 1/2

Gasline access

3 ¼ x 2 1/2"

1

The appliance and its individual shutoff valve must be disconnected

from the gas supply piping system during any pressure testing of that

system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system by

closing its individual manual shutoff valve during any pressure testing

of the gas supply piping system at test pressures equal to or less than

1/2 psig (3.5 kPa).

WARNING:

Do not allow fans to blow directly into the fireplace. Avoid

any drafts that alter burner flame patterns.
Keep appliance area clear and free from combustion mate-

rials, gasoline and other flammable vapors and liquids.

Unusually tight construction is defined as construction where:

Walls and ceilings exposed to the outside atmosphere have a

continuous water vapour retarder with a rating of 1 perm ( 6x 10

-11

kg per pa-sec-m

2

) or less with openings gasketed or sealed, and

Weather Stripping has been added on openable windows and

doors, and

Caulking or sealants are applied to areas such as joints around

window doors and frames, between sole plates and floors, be-

tween wall-ceiling joints, between wall panels, at penetrations for

plumbing, electrical and gas lines, and at other openings.