Maintenance

WARNING:

Do not attempt to clean the fireplace when hot.

CAUTIONS

Fireplace gas control must be in the “oFF” position and

pilot and main burners extinguished when cleaning ap-

pliance with a vacuum.

Doors and logs can get very hot. Handle only when

General

Have the fireplace installation inspected yearly, including a visual

check of the burner and the pilot flame. For your convenience a

1/8" manifold pressure tap is supplied on the gas valve for a test

gauge connection. See Figure 11.

For Natural gas this appliance requires a minimum inlet pressure

of 5.5" W.C. and a manifold pressure of 3.5" W.C.

For Propane gas this appliance requires a minimum inlet pres-

sure of 11" W.C. and a manifold pressure of 10" W.C.

Always keep the fireplace area clear and free of combustible

materials, as well as gasoline and other flammable vapours and

liquids.

Do not use this appliance if any part has been under water. Imme-

diately call a qualified service technician to inspect the appliance

and to replace any part of the control system and any gas control

which has been under water.

Operating Instructions

Lighting Instructions

See page 7.

Burner Adjustment

The C34-VF is equipped with an adjustable burner, allowing you to

raise or lower the flames. To adjust the flames, locate the black knob

marked 'Hi-Lo', in the centre of the gas control valve (See Figure 10).

The front burners are not adjustable.

n

To raise the flame height, turn the black knob (located behind the

lower trim) counterclockwise.

n

To lower the flame height, turn clockwise.

Figure 10.

'Hi-Lo' Adjustment on the C34-VF's gas valve.

Cleaning

When the fireplace is first activated, there may be some smoking.

This is a normal condition, and is the result of burning of protective

coatings on new metal.

Silicone seals on inner door during initial firing will "off gas", leav-

ing a visual deposit of a white substance on combustion chamber

walls. This can easily be removed using normal household prod-

ucts.

Use a vacuum cleaner or whisk broom to keep the control com-

partment, burner, and firebox free from dust and lint.

Logs may be cleaned periodically with a vacuum to remove soot