Operation - model ht34-pv-f – Montigo HT34 PV User Manual

Page 13

Advertising
background image

Page 13

HT34-PV Series Power Vent Gas Fireplace

Part No. XG0530 - 041510

Operation - Model HT34-PV-F

with American Flame Electronic Ignition

For Your Safety - READ BEFORE LIGHTING:

with Proflame SIT Electronic Ignition

WARNING:

If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.

To Turn Off Gas To Appliance:

Lighting Instructions:

If you cannot reach your gas supplier, call the Fire

Department.

C. Use only your hand to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service techni-
cian. Force or attempt to repair may result in a fire or explo-
sion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system,
and any gas control which has been under water.

A. This appliance is equipped with an ignition system that

lights the pilot burner automatically. Do not attempt to light
the pilot by hand.

B. BEFORE LIGHTING smell all around the appliance

area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.

What To Do If You Smell Gas:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any

phone in your building.

Immediately call your gas supplier from a neighbour's

phone. Follow the gas supplier's instructions.

1. Turn off remote switch.

2. Remove the lower Horizontal access panel.

3. Turn the incoming gas control valve to "Off".

4. Replace the lower Horizontal access panel.

1. STOP! Read the safety information above on this label.

2. Remove the lower Horizontal access panel.
3. Turn Incoming gas valve to the ON" position.

4. Wait 5 minutes to clear out any gas. If you smell gas,

STOP! Follow "B" in the safety information above on this
label. If you don't smell gas, go to the next step.

5. Turn wall switch "ON".

6

. If the Fireplace does not light, the System will cycle through

two trials, (one minute audible clicking, thirty seconds of
silence, and then another one minute of audible clicking).
If the system locks out due to inadequate gas flow, refer to
"Troubleshooting", Page 20.

7.

After completion of the information in the Troubleshooting

section, Repeat step 5.

8.

If the system will not function correctly, follow the instruc-

tions "To Turn Off Gas To Appliance" and call your service
technician or gas supplier.

EV1 (Pilot
burner)

EV2 (Main
burner)

Pilot Adjust Screw

Lockout Reset Key

Diagnostic Terminal

Power

Command (Wall
switch)

Pilot Sensor

Igniter

Ground
EV1 (Pilot burner)

EV2 (Main burner)

Gas "Out"

Gas "In"

Incoming Gas
Line, Shut-off
Valve

To fireplace
Main burner

HT34-PV-F

Advertising