Installation, Wiring, Page 9 ht34-pv series power vent gas fireplace – Montigo HT34 PV User Manual

Page 9: Gas control and pilot wiring, Wiring for the optional fan kit

Advertising
background image

Page 9

HT34-PV Series Power Vent Gas Fireplace

Part No. XG0530 - 041510

Installation

Wiring

Gas Control and Pilot Wiring

HT34-PV-I

Figure 26.

Wiring for the HT34-PV-I with Honeywell gas control and pilot.

Wiring for the optional Fan Kit

All HT34-PV Series fireplaces may be equipped with optional fan kits

for circulating heat into the living space.
Installations in Canada which employ the fans must be electrically

grounded in accordance with CSA C22.1 Canadian Electrical Code

Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded in

accordance with local codes or, in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70-1987.
For more information see the Fan Kit Installation Guide included with

the fan kit.

NOTE:

If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.

Figure 27a. Wiring schematic for optional fans.

G

L2-WH

L1-BLK

p g

Quick Connect

lu to motor

5/1/60 Supply

G

L1 L2

Honeywell (Q3450)
Pilot Assembly

Pilot Electrical
Harness Connector

Honeywell Gas
Control (SV9501M)

Gas Control
Connector

Junction Box

115VAC
24VAC

40 VA
Transformer

Black

White

Green

Gnd Screw

Wall Switch

Fan Plug
Receptacle