Part No. XG0105A

ME34-DV Modular Fireplace

Installation

Figure 23a.

Wiring for optional air circulating fan kit.

Wiring for the

optional Fan Kit

All 34 Series Modular fireplaces feature an optional fan kit for circulat-
ing heat into the living space.
Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded
in accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70-1987.
For more information see the Fan Kit Installation Guide included
with the fan kit.

NOTE:

If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.

G

L1-WH

L2-BLK

Quick Connect

plug to motor

Figure 23b.

Wiring schematic for optional fan kit.

115/1/60 Supply

G

L1 L2

Installing the Log Set

Installing the Logs:

The ME34-DV is supplied with four (4) fibre logs. Logs 'A' and 'B' are
factory installed on the mounting slots. They should be positioned as
shown in figure 24a. Place log

"C" and log "D" onto the mating posi-

tions as shown below in figure 24b.

Figure 24a.

Logs 'A' and 'B' shown in factory-installed positions.

Figure 24b.

Completed log installation. Logs 'C' and 'D' are placed in

their mating positions, and embers are in place.

Placing the Embers:

The ME34-DV is supplied with a small bag of embers. Place the em-
ber material along the middle of the burner between the flame shaper
and log 'A'. Do not let the ember material fall behind the burner tube.

NOTES

:

If logs are not placed properly, excessive sooting will result.

The surface of the logs will crack due to the heat from the

flames. This is a normal occurance.

Log 'B'

Log 'A'

Log 'D'

Log 'C'

Embers

Flame Shaper

Advertising