Maintenance, Troubleshooting, Gas control valve – Montigo ME34DV User Manual

Page 17: Pilot burner adjustment

Advertising
background image

Page 17

Part No. XG0105A

ME34-DV Modular Fireplace

Maintenance

Troubleshooting

If your fireplace still does not operate correctly, consult your dealer or
the manufacturer.
All service and repairs should be performed by a qualified
agency.
All spare parts, optional fans (see optional fan instruction guide), and
optional trim finishes are available from the manufacturer or your local
dealer.

Gas Control Valve

Figure 28.

Sit Nova 820 gas valve.

Pilot Burner Adjustment

1. Locate Pilot Adjustment Screw.

(See figure 28.)

2. Adjust pilot screw to provide properly sized flame as shown in

figure 29).

3. After installing or servicing, leak test with a soap solution with

main burner on. Coat pipe and tubing joints, gasket etc. with soap
solution. Bubbles indicate leaks. Tighten any areas where the
bubbles appear until the bubbling stops completely.

ME34-DV-I

Figure 29.

Pilot Burner

Troubleshooting

The following is a troubleshooting chart of possible problems:

PROBLEM

CORRECTIVE ACTION

Noisy Pilot Flame

Locate pilot adjustement screw on gas
control valve. Flame is decreased by
turning adjustment screw clockwise.

Pilot won’t ignite

Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram

figure

28.

Main burner will

1. Check wiring (

see figure 28).

not light

2. Check wall switch for proper con-
nection.

ME34-DV

Manifold Pressure

Test Connection

Pilot Adjustment Screw

Inlet

Pressure

Power

Generator

Wall Switch

Advertising