Repair Section

57

6.5 Self-Diagnostic Code Records Display Operation

(Only When Connected With WMC)

• The unit power on time, compressor operation time, and self-diagnostic codes can be displayed

on the WMC when it is connected to CM 25. The unit power on time and compressor operating

time can be stored up to 65535 hours (automatically cleared to 0 hour and start counting). The

self-diagnostic codes can be stored up to 4 different codes.

(1) Display method

• To display the unit power on time, compressor operation time and self-diagnostic codes, set the

unit to standby mode, then press and hold the “RESET” button for 3 seconds.

• Unit power on time (Ot) is a default view. Press “

” button to view the compressor operating

time (Ct) or press “

” button to view the self-diagnostic code number 4. The view sequences

are shown in the figure below.

ILL00531-01

Ot (Total Unit Power On Time)

*Displayed in reverse order using the " " button.

Self-Diagnostic Code Display 1

Self-Diagnostic Code Display 2

Self-Diagnostic Code Display 3

Self-Diagnostic Code Display 4

Ct (Compressor Operating Time)

Displayed Code

including "-- --"

Unit Power On Time/

Compressor Operation Time

Self-diagnostic Code

Display Number