Precautions – Norsat O3b 5W BUC User Manual

Page 6

Advertising
background image

Rev. 1.0

7005STC-O3B Series

DES007565

6

1.3.4

Water and Humidity

Do not expose the BUC to standing water. Failure to follow this precaution could result in electric

shock and injury to persons.

1.3.5

Installation of the BUC

The BUC described in this manual should not be installed in an unstable situation because it may

cause serious injuries to the staff as well as a severe damage to the BUC.

1.3.6

Power Supply

An external power supply is necessary to convert the input AC 230V to +48V DC, and the internal

DC/DC converter within the BUC generates appropriate DC voltages for IF, LO, Up-converter,

SSPA, and DC M&C units.

1.3.7

Equipment Working Conditions

Never perform maintenance or make adjustments to the BUC when the power supply is connected.

1.3.8

Important Safety Information

Read the chapters on Installation and System Operation before attempting to switch on the BUC.

Do not connect the AC INPUT (prime power) port to a power source until all the other connections

have been made.



Precautions

1. Do not operate the BUC without a cable or a RF load connected to the RF OUTPUT waveguide

port.

2. Never look into the waveguide opening when the BUC is powered on.

Advertising