Pipe

5.3.1

Installation rail


-

The installation location must be selected so that access to the installation rail is guar-

anteed at all times and so that the water softener can be connected to the installation
rail. The hose length is 500mm (19.7 inches).


-

Direct sunlight and heat radiation are to be avoided.
















Thread: 1/2”, female

Thread: 3/8”, female


Through borings 6mm (0.24 inches)



Together with the installation
rail a fitting is delivered
which can be used to con-
nect this unit by a PVC or
CPVC pipe (16mm outer di-
ameter).

Figure 12: Installation of the Installation Rail

CAUTION:
Except as is explicitly stated in these instructions, parts which conduct electricity as well as
all other goods may not ever be mounted or stored in the space under the installation rail
because even slight leakage from the pure water system could result in damages.


5.3.2

Water Softener

-

The water softener is to be positioned under the installation rail.


-

If at all possible, this device should be installed in a room to which only a limited cate-
gory of persons is granted access.


-

The surrounding temperature must lie between +10°C (50°F) und +30°C (86°F)
throughout the year.