Turn off the pure water PerPur unit (1).

-

Block the water supply (2) at the installation rail.

-

Pull the plug-in network part (3) out of the socket.

-

With 2041/2101: Disconnect 5 pole plug (4) at the PerPur unit.

-

Take the hoses with steel jackets (5) away from the water softener (wrench 19).

-

Take away the textile hoses (6) from the water softener and take the device away.

-

Put the new water softener in place, attach hoses, be sure that all seals are present
and in order.

-

Connect plug to the pure water system (PerPur unit).

-

Fill salt container with tablet salt and add 10 litres of water, using a pail.

-

Plug network part into the socket.

-

Open water supply. The pressure indicated by the manometer should rise. Check that
all connections are watertight (visual inspection).

-

Turn on the pure water system (PerPur unit).

The DRAABE Pure Water System (PerPur) turns on automatically in 15 minutes.