5.5

Specifications for Materials

CAUTION:
The following specifications of materials must absolutely be adhered to in every particular.
They are a part of the guarantee! Only installation materials delivered by the DRAABE
company are permissible!

5.5.1

Hoses, Pipes, Fittings

Material for pipes and fittings:

PVC pipe (grey) or CPVC pipe (white), UV resistant

or opaque, must fulfil the ASTM Standards D-2846

, ANSI/NSF Standard 14

designation:

PVC pipe (grey) or CPVC pipe (white)

requirements:

food safe, UV- opaque, inner diameter

≥ 13mm (0.51

inches)

operating pressure:

10 bar (145 psi)

temperature when used:

6-37°C (43

– 100°F)

medium:

tap water, softened water or pure water

If the outputs of two pure water systems are pooled (both work in the same tank) then the
pipes and fittings from the output should have inner diameter

≥ 16mm (0.63 inches).


5.5.2

Electrical Components

cables

use:

from water softener to the pure water system

designation:

LIYY 5 x 0,5 mm² (20 AWG)

party responsible:

delivered with DRAABE SMB


use:

network connection PerPur, pressure boost

designation:

H05VV-F 3 x 0,75 mm² (18 AWG)

party responsible:

installer or operator



wall sockets

use:

pure water system, water softener, pressure boost

technical data:

120VAC

15A

water protected

poles:

P, N, PE

party responsible:

installer or operator



plug in power supply

use:

water softener

technical data:

120Vac (primary), 12Vac (secondary)


party responsible:

delivered with DRAABE water softener