7. Connect to PC

You could use delivered cable (KS2-data2) to connect AIS data to PC as

following diagram:

8. DATA SERIAL PORT

The default baud rate of the data link is 38.4kBaud with 8 data bits, one

stop bit and no parity. The data interface conforms to IEC 61162-1.

The sent messages are VDM, VDO, RMC,and GSA are conform to

NMEA 0183. Please refer to NMEA 0183 for full details of these AIS

messages.

1.5M

9-pin serial port of the computer

2

-Receive data

KS-200A/B

2- Orange- TX Data

3- Green- RX Data

5- Black- GND

3

-Send data

5

-GND

DB9 (Male)

DB9 (Female)