„Heating“ mode

In the heating mode, you can heat the room in

spring or fall. The selected room temperature is set

using the " " and " " keys in 1 °C increments. If

the room temperature is 1 °C below the selected

target temperature, the indoor unit starts to heat

the air in the room. If the set room temperature is

exceeded by approx. 1 °C, the controller will switch

off the heater function. To protect the compressor,

the controller will wait 3 minutes before switching

on the heating mode again. The fan operation

starts only at a temperature of 32 ° C at the heat

exchanger.

Fig. 15: „Heating“ mode

The heating mode has priority!

Turns on the indoor unit to the heating mode,

switch off the other indoor units from which are

in cooling mode, the cooling. During heating

operation can not be cooled.

„FAN“ key

Function

1. Automatic

2. Low

3. Medium

4. High

Automatic function:

<ca. 1,5 °C = low level

> ca. 1,5 °C = middle level

> ca. 3,5 °C = high level

4

3

2

1

FAN

FAN

FAN

FAN

Fig. 16: "Fan" key