13. Screw the supplied protective caps onto the 4 cou-

pling halves (Fig. 16).

14. Provide for a wall lead-through Ø 60 mm .

15. After setup or assembly of the indoor unit and out-

door unit, the connecting line is attached to the in-
door unit in the reverse order (Points 12 to 1).

16. After attaching the connection, make sure that the

couplings are tightly sealed.

Cleaning the Dust Filter


The indoor unit is equipped with an dust filter. It can be
pulled out of the back of the unit. The dust filter must be
cleaned at regular intervals.
To clean the dust filter, proceed as follows:
1. Remove the dust filter. (Fig. 17).
2. Clean the dust from the filter.

If the filter is only slightly dirty, you can use a vac-
uum cleaner.

◊ The unit may only be cleaned with a clean, soft and

slightly damp cloth which is used to carefully wipe the
dirt from the surface.

◊ Only use warm water.

Maximal 40 °C warm.

◊ Thoroughly clean the air output and intake openings

on a regular basis.
In our experience, this is the first place where dirt
accumulates.

◊ Never forget to clean the water tank on a regular basis.
◊ Do not use aggressive cleansers or cleaning prod-

ucts containing solvents.

◊ Never clean the unit under a stream of water.

3. If the dust filter is very dirty, clean it carefully in

warm water.

4. Then let the filter air dry.

5. Reinsert the filter into the unit

In case of extreme dirt the dust filter is to be replace.

*

Never use the unit without installed dust filter!
Without a dust filter the plate fins of the evapora-
tors would become dirty and the capacity of the
unit would be decreased.

Fig. 17

Dust filter

Comments about detaching the connection line:

◊ The units may only be detached right before mount-

ing and they should only remain disconnected as
long as absolutely necessary.

◊ Before the lines are reconnected, make sure that no

dirt, moisture or other foreign matter has adversely
affected proper functioning of the couplings.

◊ Reattach the fastening clamp after the lines have

been connected.

◊ The lines should only be detached and reconnected

by authorised personnel.

◊ The unit can be detached and reconnected approxi-

mately 10 times when done properly without any
noticeable decline in cooling performance.

Fig. 16

Protective
caps

Protective
caps

Maintenance and Service


Regular care and the observation of a number of basic
rules will ensure the dehumidifier’s long service life and
reliable operation.

The unit should be inspected and cleaned thoroughly
after each long period of operation, at a minimum once
a year.

All moving parts have been permanently lubricated.

The complete cooling system is a closed-loop system
that requires little maintenance. It may only be ser-
viced by authorised repair centres.