Unit Shut Down


To shut down the unit, always switch it off with the On /
Off button on the control panel. Only now can you un-
plug it on the power supply.
Never shut the running unit off by pulling the power plug.

Storage

If the unit is to be taken out of operation for a longer pe-
riod of time, for example, over the winter, proceed as
follows:

1. Empty the internal water tank via the water drainage

tube on the back of the indoor unit.

2. To do this, remove the tube from its holder and re-

move the sealing cap.

3. Collect the water that drains out.

4. Reinsert the sealing cap and place the tube securely

in its holder.

5. Let the unit run for approximately 3 hours in circulation

mode.
This removes any remaining moisture from the unit.

6. Switch the unit off with the On / Off switch.

7. Unplug the power cable and wind it up.

It can be attached to the back of the indoor unit.

Safety screw M4

Mounting on an outside wall with straps

Another way to attach the outdoor unit to a wall or to a
parapet in the outer area is to use straps.

1. Hook the wall holders onto the outdoor unit and se-

cure them with the M4 safety screws.

Here, the wall holders maintain the proper distance
to the wall.

2. Hook one end of the strap into the fastening loops

on the outer part with the snap hook.

3. Hang the other end of the strap into the loop screws

attached to the wall or parapet (Fig. 10).

Make sure the fasteners are securely attached.

Mounting height

The outdoor units (lower edge) may only be mounted a
maximum of 1.8 m above the setup height of the indoor
unit (Fig. 11).

The condensation pump is only guaranteed to pump
condensation that builds up in the indoor unit to the out-
door unit up to this height.

If the outdoor unit is mounted below the setup height of
the indoor unit, a distance of 1.5 m may not be ex-
ceeded.

353

mm

Fig. 10

Loop screw

Safety screw M4

Snap hook

Fastening loop

Fig. 11

20 cm

max

. 1,8 m

*

Depending on the weather, water may drain out of
the water outlet on the back of the outdoor unit.
This is a normal occurrence.
Select the location for mounting the outdoor unit
in such a way that the outcoming water does not
cause any damage.